Progressing cavity

PCP Drive Heads

A rugged, low-maintenance drive head for progressing cavity pumps, with an optional permanent magnet direct drive.

PMMdirect drive option
VFDor sheave speed
Hydraulicbackspin brake
Drag to rotate

Design features

Improved Reliability

Proprietary design minimizes maintenance and requires little lubrication.

Easy Speed Adjustments

Easily adjust RPM through VFD or mechanically adjust RPM through Sheave sizing

Permanent Magnet Motor (Optional)

The streamlined PMM direct drive head design, with minimal components, eliminates the need for gear reducer transmission.

Others

Either horizontal mounted or vertically mounted on wellhead with adapters; Hydraulic Braking System for controlled release of back spin.

On site

PCP drive head technical details

PMM direct-drive head

The ULT PMM direct-drive head pairs a high-torque permanent magnet motor directly with the wellhead. It removes the belts, sheaves and gearbox of a conventional drive head, which cuts maintenance and maximizes electrical efficiency.

Applications

  • Thermal and heavy oil: high-torque production in demanding thermal recovery and heavy oil wells
  • High-volume artificial lift: built for high-load, variable-flow wells that need continuous run-time
  • System modernization: a direct, high-efficiency upgrade for conventional VFD and mechanical drive heads

Features

  • Compact, lightweight footprint that simplifies wellhead installation and reduces rig time
  • Full rated torque across the entire operating speed range
  • No belts or gears to wear, cutting field maintenance costs
  • Dual-layer braking: an automated, controlled slow stop plus an immediate failsafe mechanical brake for power-loss protection
  • High breakout torque to overcome static friction from sand, wax or scale
  • High efficiency across a wide operating range and a high power factor that lowers utility costs

Controls

  • Variable speed drive (VSD) for precise pump speed optimization
  • On shutdown, the VSD manages reverse rotation to safely dissipate rod string backspin energy
  • SCADA ready with native Modbus RTU and Modbus TCP/IP interfaces
PMM drive head specifications
Model10-45012-45016-45020-45024-450
Rated torque, N·m9501,1871,5831,9792,375
Rated torque, ft·lbf7018761,1681,4591,751
Rated speed, rpm450 (customizable)
Power, kW45567593112
Power, HP6075100125150
Rated frequency, Hz37.537.5606060
Rated voltage, V380 / 460
Overload torque (60 s), N·m1,4251,7812,3752,9683,562
Overload torque (60 s), ft·lbf1,0511,3141,7512,1892,627
BrakeFailsafe electromagnetic
Brake torque, N·m600–800 (customizable)800–1,200 (customizable)
Polished rod size, in1-1/4 and 1-1/2 (continuous sucker rod optional)
Axial load, t1219 to 30 (customizable)
Axial load, lbf26,45641,888 to 66,139 (customizable)
Frame315355
Wellhead flange3-1/8", 4-1/16" or 5-1/8", 3,000 / 5,000 psi
ProtectionIP54
Operating temperature, °C−40 to 50
Motor dimensions, mmØ700 × 700Ø820 × 900
Overall dimensions, mmØ700 × 1,800Ø820 × 2,100
Weight, kg8909701,4201,5201,670

Designs can be customized to customer specifications and are subject to change without notice.

PCP drive head FAQ

What does a PCP drive head do?

The drive head sits on the wellhead and turns the rod string that drives the rotor of the progressing cavity pump downhole. It carries the rod string's axial load and controls backspin when the pump stops.

What is a PMM direct-drive head?

A drive head that pairs a high-torque permanent magnet motor directly with the wellhead. With no belts, sheaves or gearbox it needs less maintenance, and it is lighter, safer, quieter and more energy-efficient than a conventional AC motor drive head.

How is backspin controlled?

The conventional drive head uses a hydraulic braking system for a controlled release of backspin. On the PMM direct-drive head, the VSD manages reverse rotation on shutdown, backed by a failsafe electromagnetic brake for power-loss protection.

What torque and power ratings are available?

Five PMM direct-drive models from 950 to 2,375 N·m (701 to 1,751 ft·lbf) rated torque and 45 to 112 kW (60 to 150 HP), at a rated 450 rpm. Axial load ratings run from 12 t up to 30 t, with 3-1/8, 4-1/16 or 5-1/8 in wellhead flanges.

Which applications suit a PMM drive head?

Thermal and heavy oil wells that need high torque, high-volume wells that need continuous run time, and upgrades of conventional VFD and mechanical drive heads. It runs from −40 to 50 °C and is SCADA ready with Modbus RTU and Modbus TCP/IP.

How do I adjust drive head speed?

Through the VFD, or mechanically by changing sheave sizes on a belt-driven head.

Learn how it works